Section 1 - General Safety Practices
1-2
31200029
1.3 OPERATION SAFETY
Electrical Hazards
This machine is not insulated and does not provide protection from contact or
proximity to electrical current.
Maintain safe distance from electrical lines, apparatus or any energized (exposed
or insulated) parts according to the Minimum Safe Approach Distance (MSAD).
Allow for machine movement and electrical line swaying.
Voltage Range
(Phase to Phase)
MINIMUM SAFE APPROACH
DISTANCE (MSAD)
0 to 300 V AVOID CONTACT
Over 300 V to 50 KV 3 m (10 ft)
Over 50 KV to 200 KV 5 m (15 ft)
Over 200 KV to 350 KV 6 m (20 ft)
Over 350 KV to 500 KV 8 m (25 ft)
Over 500 KV to 750 KV 11 m (35 ft)
Over 750 KV to 1000 KV 14 m (45 ft)
Note: This requirement shall apply except where employer, local or
governmental regulations are more stringent.
OZ1760