SECTION 6 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
3121249 – JLG Lift – 6-3
Continuity Measurement Current Measurement
Figure 6-3. Continuity Measurement Figure 6-4. Current Measurement (DC)
Some meters require a separate button press to
enable audible continuity testing
Circuit power must be turned OFF before testing con-
tinuity
Disconnect component from circuit before testing
Use firm contact with meter leads
First test meter and leads by touching leads together.
Meter should produce an audible alarm, indicating
continuity
Set up the meter for the expected current range
Be sure to connect the meter leads to the correct
jacks for the current range you have selected
If meter is not auto ranging, set it to the correct range
(See multi meter’s operation manual)
Use firm contact with meter leads